Nfluke clamp meter pdf

Astroai digital clamp meter, trms 6000 counts multimeter volt amp ohm meter with manual and auto ranging, continuity. Clamp meter selection chart job functions applications recommended clamp general purpose plant maintenance multiple placement potential for large facilities allows units to be left in place 365 truerms ac clamp meter. Ideal tightsight clamp meter allows you to safely and easily view the current measurement due to the exclusive back lit tightsight display located on the bottom of the clamp meter. Ac clamp meter this is a 3 3 4 9999 counts backlit lcd display, ac current clamp meter. Also, it is optimized for 5060hz sine waves, so will not measure the current from the esc to the motor which is at a much higher frequency and a. Looking for fluke clampon power meter kit, 1200kw, 1400a 1fbk2. The fluke 322 clamp meter is designed to verify the presence of load current, ac voltage and continuity of circuits, switches, fuses and contacts.

The fluke 323 clamp meter is a good basic troubleshooting tool for commercial and residential electricians. Designed to clamp around a conductor, clamp meters provides the means of measuring ac or dc current without the need to make breaks in insulation, saving time, money and effort when testing. An electrical meter with integral ac current clamp is known as a clamp meter, clampon ammeter, tong tester, or colloquially as an amp clamp. Fully safety jaw ergonomic overmolded body gives convenient onehand operation large easytoread display with 0.

Over the years current clamp meters have evolved to include a host of additional features. Use this clampon multimeter to test amperage up to 2500a. Dcac clamp meter tes3092tes electrical electronic corp. It is the portability and size of these devices that makes them easy to carry and.

Learn how to use klein tools clamp meters and digital multimeters. The clamp meter is also very useful to probe circuits which cannot be dismantled. Depending upon the manufacturer and the model in question, the size, shape and capabilities of the clamp meter in question will vary. Acdc digital clamp meter safety information damaged in transit. Hioki clamp meters are bestinclass measuring devices incorporating hioki s expertise in current sensing technology. Job functions applications key features recommended clamp electrical contractor working on panels and branch circuits measure loads on a branch circuit at a panel including feeder cables. Covid 19 release power parameters are staying abreast of the fast moving status of covid19.

Harmonious power clamp meter manufacturer mastech supplies power clamp meter,power clamp meters,ms2205. Have the meter serviced only by qualified service personnel. Examine the test leads for damaged insulation or exposed metal. How to choose between a clamp meter and digital multimeter klein tools. Browse a variety of top brands in clamp meters such as extech, ironton, and milwaukee from the product experts. Clamp meters the meter 11 display hold min max avg 1x 2x 3x 2 sec exit.

Fluke 375 fc true rms acdc clamp meter clamp meters. Easy onehand operation make this meter perfect for the working installer or tradesman. Fluke clampon power meter kit, 1200kw, 1400a 1fbk2. Harmonious power clamp meter ms2205digital clamp meters. Uei clamp meters a clamp meter combines a current clamp with the basic functions of a digital multimeter, also called dmm. The fluke 381 is a handheld, batteryoperated clamp meter the meter that has a remotedisplay module and detachable iflex flexible current probe. Analog clamp meter mcp9a analog clamp meter includes test leads atl55a batteryformally dl49 2 aaa zippered carrying pouch manual dl235 truerms specialty clamp meter clampon meters dl49b digital clamp meter includes g2phoenix pro dl379 g2phoenix hook ch3 ktype temperature probe att29 test leads atl59 atl55a battery 2 aaa manual zippered. Clamp meter safety information 5 to avoid false readings that can lead to electrical shock and injury, replace the batteries as soon as the low battery indicator appears. A range of 1 ma to 80 a acdc means the small size does not compromise on range or accuracy.

Fluke multimeters and clamp meters are common industrial test meters used to evaluate voltage, current, frequency and resistance of both ac and dc circuits. Clamp meters the meter 9 the meter clamp meter fig01. Hioki clamp meters are bestinclass measuring devices incorporating hiokis expertise in current sensing technology. Detachable jaw makes accessing wires and viewing the. Dc clamp meters fluke 374 fc truerms acdc clamp meter. Clamp meter safety information 3 remove the test leads from the meter before the battery door is opened. Find great deals on ebay for dc amp clamp meter and dc current clamp meter.

And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. In contrast to a multimeter, the clamp meter does not need to be connected to the circuit in order to read current. The digital multimeter features an easytoread lcd display and an automatic zero adjust for. To see, print, or download the latest manual supplement, visit page 7. With the addition of dc current and frequency, it has everything youll need to troubleshoot. This is a quality, intermediatelevel clampmeter with more than useful current ranges up to 400 amps ac and dc. The fluke 325 truerms clamp meter is a reliable, versatile troubleshooting tool for commercial and residential electricians, featuring truerms measurements, a slim design for easy transport and use, and a large display for efficient troubleshooting. The new fluke 362 clamp meter is designed to fit easily in your pocket. A clamp meter is a tool for measuring current on a wire. The small 18 mm triangular jaw allows access into tight places where other clamp meters cant reach, while providing the accuracy you can trust from a fluke tool. Acdc ma clamp meter prova11tes electrical electronic corp. Confidently take reliable readings with the true rms, fluke 355 digital clamp meter the tool of choice for high current clamp on amp meter measurement up to 2000 a.

We dont know when or if this item will be back in stock. This fluke product will be free from defects in material and workmanship for three years from the date of purchase. Model cm4371 is a 600a true rms clamp meter that features stronger jaws, broader 25. Fluke 323 truerms clamp meter delivers rugged reliable performance for general electrical troubleshooting. By checking this box, i agree to receive marketing communications and product offers by email from fluke electronics corporation, transacting under fluke industrial, or its partners in accordance with its privacy policy.

The fluke 373 clamp meter the meter measures truerms ac and dc voltage, ac current, resistance, and capacitance. The fluke 322 also offers dc voltage measurements and has a higher resolution for loads below 40 ah. Fluke 325 clamp metertruerms clamp multimeter fluke. Hioki clamp on hitester 329150 to be discontinued add to quote. View and download fluke 365 calibration manual online. Before using check whether the insulation on test leads has been. Clamp the jaw around a conductor to measure current. It is ce approved and has auto power off, data hold relative measurement and non contact voltage detector functions. The fluke 374 fc clamp meter is the direct replacement for the fluke 374 clamp meter. An ac clamp meter basically consists of a current transformer in its jaws, bar ct usually. It is used to measure ac current upto a ac, acdc voltage, resistance, capacitance frequency, duty cycle, diode and contiunity. Never make current measurement on a circuit above 60v acdc. Our key priority is always the health, wellbeing and safety of our staff as well as ensuring business continuity of power parameters operations. Ordering information 323 truerms clamp meter 324 truerms clamp meter 325 truerms clamp meter included with all models clamp meter, test leads, soft case, and users manual.

How to measure power with a clampon watt meter figure 1 using a clampon meter with the ac line splitter model als1. Fluke clamp meters solutions for every need 355 773 more solutions inside. Additionally, it is compatible with the new iflex flexible current probe sold separately, which expands the measurement range to 2500a ac. Measure 4 to 20 ma signals without breaking the loop just like the. Fluke clamp meter 323 truerms digital clamp meter fluke. Versatile and rugged tools for applications with high currents. With truerms ac voltage and current measurements, the 374 fc enables you to accurately troubleshoot nonlinear signals. You will have to use another device to measure the voltage and the clamp meter will give you the current intensity values. Hioki ac clamp meter 328020f to be discontinued add to quote. High current and a large jaw, make these clamps well suited for industrial and utility applications. Clampstyle multimeter lets you make instant tests and measurements without disconnecting wires.

General technologies corp gtc cm100 1 ma to 100 amps acdc low current clamp meter. Introduction the solar100 measures the solar energy and radiation, the typical application for this model are. How to choose between a clamp meter and digital multimeter. Todays clamp meters have most of the basic functions of a. Built on success, digital clamp meters designed by fluke are known as workhorse current clamp meters. A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents. It includes true rms measurements, optimized ergonomics, and large display for efficient troubleshooting. The line voltage is measured and found to be 102v ac. When servicing the meter, use only specified replacement parts. The fluke 323, 324 and 325 clamp meters are designed to perform in the toughest environments and provide noisefree, reliable results users can trust to. It gets rid of the unnecessary procedure of breaking the circuit to measure current.

When the meter is in acv or aca function, thd%f values up to 99 thd% will be displayed in the secondary mini display automatically. Fluke 345 power quality clamp meter has a bright color display to analyze the harmonic spectrum, a lowpass filter to remove high frequency noise, and a high emc immunity design, the fluke 345 is ideal for measurements on switching loads such as variable frequency drives. Clampon ammeter or simply clamp meter is an instrument that is used to measure the current flowing through a conductor. This instrument fits neatly in the hand and with a clamp opening of 18mm it is ideal for those instances where it is hard to reach cables. This small and rugged meter is ideally suited for current measurements in tight cable compartments. Digital clamp meters can measure magnitudes such as electrical power and serve as energy analyzers. Digital multimeter dmm, but with the added feature of a current transformer built into the product. Fluke test and measurement tools product catalogs fluke. With advanced performance, the amp clamp meter line is designed to be simple to use and gimmickfree. A compact clamp meter for use where access to cables is a problem.